Magnum V8-5.7L (2008)
Blower Motor: Service and Repair
Installation
INSTALLATION
NOTE: LHD model shown. RHD model similar.
1. Position the blower motor (2) into the HVAC housing (4).
2. Install the four screws (3) that secure the blower motor to the HVAC housing. Tighten the screws to 2.2 Nm (20 in. lbs.).
3. Connect the wire harness connector (1) to the blower motor and engage the wire harness connector locking tab.
4. Install the HVAC wire harness retainers onto the blower motor.
5. Install the instrument panel silencer onto the passenger side of the instrument panel See: Body and Frame/Interior Moulding / Trim/Dashboard /
Instrument Panel/Service and Repair/Silencer Panel - Installation
6. Reconnect the negative battery cable.