1. Disconnect and isolate the negative battery cable.
2. Remove the glove box from the instrument panel  See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and

Repair/Instrument Panel Glove Box - Removal .

3. Remove the two screws (1) that secure the recirculation door actuator (2) to the side of the HVAC air inlet housing (3).
4. Remove the recirculation door actuator from the air inlet housing and disconnect the HVAC wire harness connector (4) from the actuator.
5. Remove the recirculation door actuator from the vehicle.

Recirculation Door Actuator - Installation

INSTALLATION

1. Install the recirculation door actuator (1) onto the side of the HVAC air inlet housing (2). If necessary, rotate the actuator slightly to align the

splines on the actuator output shaft (3) with those in the recirculation door actuator coupler (4).

Blend Door Actuator - Removal|Page 10926 > < Blend Door Actuator - Removal|Page 10924