30. Position the blower motor resistor (7) and the blower motor (2) into the bottom of the HVAC housing (5).
31. Install the screws (4) that secure the blower motor to the HVAC housing. Tighten the screws to 1.7 Nm (15 in. lbs.).
32. Install the screws (6) that secure the blower motor resistor to the HVAC housing. Tighten the screws to 1.1 Nm (10 in. lbs.).
33. Connect the HVAC wire harness connectors (1 and 3) to blower motor resistor and the blower motor.

34. Position the recirculation door actuator (3) onto the air inlet housing (4) and install the retaining screws. Tighten the screws to 1.1 Nm (10 in. lbs.)
35. Position the mode door actuators (1) and the blend door actuators (2) onto the HVAC housing (5) and install the retaining screws. Tighten the

screws to 1.1 Nm (10 in. lbs.).

36. Connect the HVAC wire harness connectors to the actuators.
37. Install the HVAC housing  See: Removal and Replacement/HVAC Housing - Installation .
38. If the A/C evaporator is being replaced, add 60 milliliters (2 fluid ounces) of refrigerant oil to the refrigerant system. When replacing multiple A/C

system components, refer to the Refrigerant Oil Capacities chart to determine how much oil should be added to the refrigerant system  See:
Service and Repair/Refrigerant Oil Level . Use only refrigerant oil of the type recommended for the A/C compressor in the vehicle.