dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Defroster Duct - Removal|Page 5707 > < Blend Door Actuator - Removal|Page 5702
Page 1
background image

Air Duct: Service and Repair
Defroster Duct - Removal

REMOVAL

WARNING: Disable the airbag system before attempting any steering wheel, steering column or instrument panel component diagnosis or

service. Disconnect and isolate the negative battery (ground) cable and wait two minutes for the airbag system capacitor to
discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to follow
these instructions may result in accidental airbag deployment and possible serious or fatal injury.

NOTE: Take the proper precautions to protect the instrument panel from cosmetic damage.

1. Remove the instrument panel and place it on a workbench See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service

and Repair/Instrument Panel - Removal.

2. Remove the instrument panel cover See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument

Panel Cover - Removal.

3. Remove the instrument panel ducts and place the center distribution duct on a workbench See: Instrument Panel Duct - Removal.
4. Remove the three retainers (3 and 4) that secure the defroster duct (1) to the center distribution duct (2) and remove the defroster duct.

Defroster Duct - Removal|Page 5707 > < Blend Door Actuator - Removal|Page 5702