RAM 3500 Chassis Cab Truck 2WD L6-6.7L DSL Turbo (2010)
Coupler HVAC: Description and Operation
Refrigerant Line Coupler - Operation
OPERATION
The spring-lock type refrigerant line coupler is held together by a garter spring (6) inside a circular cage (7) on the male half of the fitting (1). When the
two coupler halves are connected, the flared end of the female fitting (2) slips behind the garter spring inside the cage on the male fitting. The garter
spring and cage prevent the flared end of the female fitting from pulling out of the cage. Some applications use a connection indicator ring (4) to help
indicate when the two coupler halves are fully connected.
O-rings (8) are used to seal the coupler connections. These O-rings are compatible with R-134a refrigerant and must be replaced with O-rings made of
the same material.
A secondary retaining clip (3) is installed over the connected coupler (5) for added protection.