Stratus Coupe V6-3.0L VIN H (2001)
2. Measure the voltage between terminal 21 and ground.
Q: Is the voltage approximately 12 volts (battery positive voltage)?
YES: Go to Step 8.
NO: Go to Step6.
STEP 6. Check combination meter connector C-102 for damage.
Q: Is combination meter connector C-102 in good condition?
YES: Go to Step 7.
NO: Repair or replace it. Refer to Harness Connector Inspection. The high-beam indicator light should work normally.