All Other Service Bulletins for Air Duct: > < Heater - Insufficient Heat To Front Seat Floor Area|Page 5091
Page 3
background image

b. If stripping occurs, use a pop rivet or a # 10 screw to secure.

NOTE: A SELF-TAPPING SCREW MUST BE USED SINCE THERE IS NO HOLE EXISTING IN THE BOTTOM OF THE CASE.

5. Operate the system and check to see that heat flows from the new extension.

6. Be sure that any holes accidently placed in the bottom of the plenum are sealed to prevent condensate from dripping on the floor.

CAUTION:

AFTER INSTALLING THE EXTENSION, BE SURE THE ACCELERATOR CABLE CONNECTION TO THE ACCELERATOR
PEDAL IS OKAY.

PART NUMBER

PART NAME

CLASS

FO9Z-18C299-B

Passenger Side Floor Duct

C

Extension

FO9Z-18C299-C

Driver Side Floor Duct

C

Extension

OTHER APPLICABLE ARTICLES: None
WARRANTY STATUS:

Eligible Under Basic Warranty Coverage

OPERATION     

DESCRIPTION

TIME

900909A

Install Extension Ducts

0.5 Hr.

DEALER CODING

BASIC PART NO.         

CONDITION CODE

18C299

90

OASIS CODES:

2620, 2630, 2631