ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Condenser to Evaporator Line|Page 6799 > < Hose/Line HVAC|Description and Operation
Page 1
background image

Hose/Line HVAC: Service and Repair
Condenser to Evaporator Line

CONDENSER TO EVAPORATOR LINE

REMOVAL AND INSTALLATION

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.

2. Remove the nut and disconnect the A/C fitting.

-

Discard the O-ring seal.

3. Disconnect the spring lock coupling at the evaporator core inlet.

-

Discard the O-ring seals.

4. Remove the condenser-to-evaporator line.

5. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean PAG oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

6. Evacuate, leak test and charge the refrigerant system.

Condenser to Evaporator Line|Page 6799 > < Hose/Line HVAC|Description and Operation