ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor Manifold and Tube Assembly|Page 2227 > < Compressor Manifold and Tube Assembly
Page 2
background image

Disconnect the compressor manifold and tube assembly suction fitting.
-

Discard the O-ring seal.

-

To install, tighten to 47 Nm (35 lb-ft).

7. CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

Disconnect condenser inlet fitting.
-

Discard the O-ring seal.

-

To install, tighten to 39 Nm (29 lb-ft).

8. Remove the compressor manifold and tube assembly.
9. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

10. Evacuate, leak test, and charge the refrigerant system.