9. Remove the main control valve body and discard the pump outlet screen.

Installation 

1. NOTE:  Make sure that the drive pin of the manual valve detent lever assembly engages the manual valve in the correct location prior to installing

the bolts.

Position the main control valve body gasket and main control valve body onto the transmission case using 2 bolts as a guide.

2. NOTE:  The main control valve body bolts will be tightened in later steps.

Loosely install the 11 long main control valve body bolts.

3. NOTE:  Lubricate the electronic pressure control (EPC) solenoid O-rings with clean automatic transmission fluid.