Accumulator HVAC: Service and Repair

    The accumulator/dryer must be replaced any time the system has been left open for more than 24 hours with the system completely
discharged, there is evidence of moisture in the system, the system is badly contaminated, there is more than five ounces of compressor oil in it,
or the accumulator/dryer is restricted, plugged or perforated. Replacement of a refrigerant line or a major component (condenser, evaporator
or seized compressor) requires replacement of the accumulator/drier. The receiver/dryer does not necessarily need to be replaced every time
there is a loss of refrigerant charge, a component is replaced or the outer shell of the unit is dented.
 

Fig. 2 Spring lock coupling removal & installation

1.

Disconnect battery ground cable.

2.

Discharge refrigerant from system.

3.

Disconnect electrical connector from pressure switch, then remove pressure switch from accumulator.

4.

Disconnect suction line from accumulator/dryer using spring lock coupling tool, Fig. 2.

5.

Remove accumulator/drier attaching screws, then using the spring lock coupling tool, disconnect drier from evaporator outlet tube and remove the