Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

All vehicles

1. Recover the refrigerant.
2. Remove the PCM.
3. Remove the low-side service port stem bracket bolt.

-

To install, tighten to 8 Nm (71 lb-in).

4. Disconnect the A/C cycling switch electrical connector.
5. Remove the suction accumulator bolt.

-

To install, tighten to 9 Nm (80 lb-in).

6. Remove the suction accumulator stud.

-

To install, tighten to 9 Nm (80 lb-in).

4.6L vehicles

7. Remove the suction accumulator-to-compressor line bracket nut at the condenser-to-evaporator line bracket.