8. Remove the 2 suction accumulator fitting nuts and disconnect the fittings.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

9. Remove the suction accumulator bracket bolt and suction accumulator.

10. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

11. Evacuate, leak test and charge the refrigerant system.