ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Suction Accumulator to Compressor Line|Page 9041 > < Suction Accumulator to Compressor Line|Page 9039
Page 3
background image

2. Recover the refrigerant.
3. Remove the air cleaner and air cleaner outlet tube.
4. Remove the compressor-to-condenser discharge line bracket nut and detach the bracket.

-

To install, tighten to 9 Nm (80 lb-in).

5. Removal the compressor outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (11 lb-ft).

6. Remove the 2 coolant expansion tank bolts and position the coolant expansion tank aside.

-

To install, tighten to 7 Nm (62 lb-in).

7. Disconnect the A/C pressure transducer electrical connector.
8. Remove the condenser inlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

9. NOTE:  The LH clip should be disconnected from the line. The RH clip should be disconnected from the cooling module.

Detach the 2 compressor-to-condenser discharge line clips at the cooling module.

10. Remove the compressor-to-condenser discharge line.
11. To install, reverse the removal procedure.

-

Install a new gasket seal and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

12. Evacuate, leak test and charge the refrigerant system.

Condenser to Evaporator Line

CONDENSER TO EVAPORATOR LINE

Suction Accumulator to Compressor Line|Page 9041 > < Suction Accumulator to Compressor Line|Page 9039