2. Using the Shift Shaft Fluid Seal Installer, install a new manual control lever shaft seal.

3. Install the manual lever in the case.

1. Slide the manual lever in the case.

2. Position the spacer in place while sliding the manual lever into the spacer.

3. Position the manual valve inner lever while sliding the manual lever and lining up the roll pin hole.

4. Install the roll pin.

4. Position the park rod in place. Push down on the park pawl and position the park rod in place.

5. While holding the park rod down, install the park rod actuating plate.

-

Tighten to 12 Nm (106 lb-in).

6. NOTE: Before installing the mechatronic assembly into the transmission case, verify presence and correct orientation of the thermal bypass valve,

pump adapter seal and center support seals. Also note that one or more of the center support seals may have remained in the mechatronic assembly
during removal and should be installed into the transmission case at this time.

Verify the 4 rubber feed tubes for the center support are in place.

1. Black feed tubes.

2. Green feed tube.

3. Blue feed tube.