background image

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. REFER to Body Control Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------

Pinpoint Test J: The HVAC Module Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

 
Pinpoint Test J: The HVAC Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 54, Manual Climate Control System for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 55, Automatic Climate Control System for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

The HVAC module communicates with the scan tool through the Medium Speed Controller Area Network (MS-CAN).

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

ABS module

 

PINPOINT TEST J: THE HVAC MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
J1 CHECK THE HVAC MODULE VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: HVAC Module C294a (Electronic Manual Temperature Control (EMTC)), C2109a (Dual Automatic Temperature Control (DATC)
without Navigation), C228a (DATC with Navigation).

-

Ignition ON.

-

For EMTC, measure the voltage between the HVAC module C294a-26, circuit SBP15 (WH/RD), harness side and ground.