ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Right Side|Page 2172 > < Right Side|Page 2170
Page 3
background image

3. Tighten the bolts in the sequence shown.
4. Position the fuel charging wiring onto the valve cover studs and connect the fuel pressure regulator vacuum hose.

5. Connect the LH ignition coil electrical connectors and the LH fuel injector electrical connectors.

6. Connect the crankcase ventilation tube to the valve cover.

Right Side|Page 2172 > < Right Side|Page 2170