background image

5. Remove the tube clamp.

6. Remove the pin-type retainers and the sight shield.

7. Disconnect the condenser inlet fitting.

-

Discard the O-ring seal.

8. Disconnect the pressure cutoff switch electrical connector.

4x2 Excursion, 4x2 F-250 and 4x2 F-350 vehicles

9. Remove the RH fender splash shield.