Removal and Installation 1. Remove the components in the order indicated in the following illustration(s) and table(s). 3 - Positive crankcase ventilation (PCV) breather hose 2. To install, reverse the removal procedure. | -
NOTE:Do not press the accelerator pedal during the initialization period as this will prevent the complete initialization of the throttle body. Turn the ignition key to position II and wait for one minute to initialize the throttle body. | | -
Turn the ignition key to the OFF position. | Removal Details Item 1 : Air cleaner outlet pipe | -
Remove the air cleaner outlet tube. | Item 2 : Throttle position (TP) sensor electrical connector | -
Disconnect the TP sensor electrical connector - Release the TP sensor electrical connector locking tang.
| Installation Details Item 4 : Throttle body | -
NOTE:Hand start each throttle body retaining bolt by three full turn's. Tighten the throttle body retaining bolts. | |