Cowl: Customer Interest
A/C - Water in Blower Motor Case

Article No.
03-18-2

09/15/03

^

BODY - WATER LEAK - CLIMATE CONTROL - 
WATER IN HEATER BLOWER MOTOR CASE

^

ELECTRICAL - CLIMATE CONTROL - WATER IN 
HEATER BLOWER MOTOR CASE

FORD: 
2000-2003 FOCUS

ISSUE

Some 2000-2003 Focus vehicles may exhibit water in the Climate Control Heater Blower Motor Case, which can be associated with an inoperable heater
blower motor resistor, blower motor, or a blown blower motor fuse.

ACTION

Inspect and seal the cowl area for water leaks when servicing a blower motor resistor, blower motor, or a blown blower motor fuse. Refer to the
following Service Procedure.

SERVICE PROCEDURE

1.

Perform Workshop Manual Section 412-00:

Climate Control System - General Information, Diagnosis And Testing, Climate Control System, Blower Motor Inoperative Pinpoint Tests.

a.

If the blower motor RESISTOR is determined to be inoperable, then replace the blower motor resistor and the blower motor assembly.
Proceed to Step 2.

b.

If the BLOWER MOTOR is determined to be inoperable or the blower motor fuse is blown, then replace the blower motor assembly.
Proceed to Step 2.

2.

Inspect for water leaks into the fresh air inlet.