Removal and Installation Removal and Installation | -
Disconnect the electrical connectors. - Remove the nut and disconnect the B+ cable.
- Remove the connector.
| | -
Remove the lower generator bolts. | | -
NOTE:Insufficient clearance does not allow the bolt to be completely removed. Loosen the upper generator bolt from the engine but do not remove it from the generator. | | -
Move the generator to the rear of the vehicle, then lift up and out of the engine compartment. | | -
NOTE:Before reassembling, place the upper bolt into the generator. To install, reverse the removal procedure. | | |