ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporator Case|Service and Repair|Page 6893 > < Evaporator Case|Service and Repair
Page 2
background image

Accumulator Mounting Bracket

8. Disconnect heater water hoses (18472) from heater core tubes and plug heater water hoses with suitable 5/8-inch and 3/4-inch plugs Cap heater

core tubes to prevent coolant loss from heater core (18476) during removal of A/C evaporator housing (19850).

Heater Water Hoses

9. Disconnect vacuum supply hose (black) from vacuum source in engine compartment.

10. Remove nut retaining A/C evaporator housing to cowl panel.

Vacuum Supply Hose

11. Inside passenger compartment, remove one screw retaining the bottom of the A/C evaporator housing to cowl panel.

12. Remove screw retaining A/C evaporator case support bracket (19A639) to cowl top panel

13. Remove nut retaining A/C evaporator case mounting bracket (19A865) to cowl top panel.

14. Disconnect wire harness connector at blower motor (18527).

Evaporator Case|Service and Repair|Page 6893 > < Evaporator Case|Service and Repair