ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4132 > < Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4130
Page 1
background image

Multiplex Communication Network: Pinpoint Tests

Test Notes

NOTE: Use Rotunda 73 Digital Multimeter and New Generation Star (NGS) Tester or equivalent to perform Pinpoint Tests.

Pinpoint Tests

The No Module Communication Test must be performed to verify power and ground to the suspect module before performing any of the following
pinpoint tests.

Do not perform any of the following pinpoint tests unless you are so instructed. Each pinpoint test assumes that a fault has been detected in the
system with direction to enter a specific diagnostic routine. Performing any pinpoint test without direction may produce incorrect results and
replacement of working components. Correct test results are dependent on the proper operation of related components/systems. It may be
necessary to correct any concerns in these areas before passing the test.

Do not replace any parts unless the pinpoint test results indicate they should be replaced.

When more than one DTC is received, always start with the first Diagnostic Trouble Code (DTC) received.

Follow correct pinpoint test procedures in order as listed. Follow each step until a condition is found.

After completing any service to the communication system, verify all components are properly reconnected, then clear all DTCs. Review New
Generation Star Tester usage, retrieve/clear continuous DTCs clearing procedure.

ISO 9141 Communication Link -- Circuit 70 (LB/W)

J1850 Communication Network -- Circuit 914 (T/0), Circuit 915 (PK/LB)

Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4132 > < Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4130