Mustang GT V8-4.6L SOHC VIN X (1998)
4. Install manual control valve detent lever spring and one bolt. Tighten to 9-11 Nm (80-97 inch lbs.).
5. Install fluid filter and grommet.
6. Install digital TR sensor on manual control lever and two shims, then loosely install bolts.
7. NOTE: PARK is the last detent when the manual control lever is full forward. Return two detents toward output shaft for NEUTRAL.
Position manual control lever in NEUTRAL.