Mustang GT V8-4.6L SOHC VIN X (1998)
22. NOTE: Tab on connector is secured by main control.
Install wiring connector into case. Inspect O-ring and replace if required.
23. Position main control valve body using the two alignment bolts as a guide.
24. Install the EPC solenoid bracket. Loosely install one long 6 mm bolt.
25. Loosely install 11 long and 12 short bolts.
26. Install manual control valve detent lever spring and one bolt.