Probe V6-153 2.5L DOHC (1994)
Applying Compressed Air Through Fluid Passages
b. Apply 57 psi or less of compressed air through fluid passages.
CAUTION: Do not apply compressed air for more than three seconds.
c. Fill clutch drum with transaxle fluid. Ensure clutch piston is fully submerged.
d. Ensure no air bubbles come from between piston and drum seal when applying compressed air.
e. Lubricate bearings, then install them on both sides of reverse and forward drum.