ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Electrical Specifications|Page 4330 > < Electrical Specifications|Page 4328
Page 2
background image

Manual Lever Position Switch

Use the chart to determine which terminals to check between.

8.

Tighten the MLP switch bolts to 8-10 Nm (71-88 lb in).

9.

Connect the MLP switch electrical connector.

10. Ensure that the MLP switch shaft is still aligned with the neutral mark.

11. Install the transmission shift cable on the park actuator support.

12. Install the engine air cleaner. 

13. Connect the battery ground cable.