ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Torque Converter|Flow of Diagnosis|Page 5820 > < Torque Converter|Flow of Diagnosis|Page 5818
Page 4
background image

8. Rotate torque converter and tool then reinstall into press with tool up.
9. Secure press. Apply enough force from press to seal tool into torque converter.

WARNING: ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS. 

10. Apply air pressure 80 psi (MAX) to valve on leak check tool.

NOTE:  Use clean dry shop air.

11. With air pressure applied to valve, inspect for leaks at converter hub, seams and studs. A soap bubble solution may be applied around those areas

to aid in diagnosis. If leaks are present, replace converter.

Torque Converter|Flow of Diagnosis|Page 5820 > < Torque Converter|Flow of Diagnosis|Page 5818