Is the voltage greater than 10 volts?

Yes

GO to P2.

No

VERIFY the Smart Junction Box (SJB) fuse 35 (10A) is OK. If OK, REPAIR the circuit. If not OK, Refer to the Wiring Diagrams to identify the
possible causes of the short circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
P2 CHECK THE PAM GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Measure the resistance between the PAM C3267-4, circuit GD147 (BK/YE) or circuit GD148 (BK/YE), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to P3.

No

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
P3 CHECK ISO 9141 CIRCUIT VDB10 (GY) FOR AN OPEN BETWEEN THE PAM AND THE DLC

-

Measure the resistance between the PAM C3267-8, circuit VDB10 (GY), harness side and the DLC C251-7, circuit VDB10 (GY), harness side.

-

Is the resistance less than 5 ohms?

Yes

GO to P4.

No