gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Air Conditioning Switch > < Accumulator HVAC|Specifications|Page 6905
Page 2
background image

2. The (orifice) screen experiences continued or repeated plugging.

3. An evaporator fails because of internal and external corrosion.

REMOVE OR DISCONNECT 

1. Negative battery cable.

2. Refrigerant from the system.

3. Electrical connection (154).

4. Inlet line (108) at the accumulator (4).

5. Evaporator outlet line (158) at the accumulator (4).

-

Cap or plug the open lines.

6. Clamp (150) and screw (148).

7. Accumulator (4).

IMPORTANT:  Drain excess refrigerant into a clean container. Measure and add new oil.

INSTALL OR CONNECT 

1. Clamp (150) to the accumulator (4).

2. Accumulator (4) to the evaporator core (143) with screw (140).

3. Inlet line (108) from the evaporator core (143).

IMPORTANT:  Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.

-

Use clean 525 viscosity refrigerant oil on the seals.

-

Tighten connections to 24 Nm (18 ft. lbs.).

4. Electrical connection (154).

5. Negative battery cable.

6. Refrigerant to the system.

-

Evacuate, charge and leak test.

Air Conditioning Switch > < Accumulator HVAC|Specifications|Page 6905