honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Fresh Air/Recirculation Actuator|Page 3154 > < Fresh Air/Recirculation Actuator
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Mode Control Motor

Fig. 12 Function (mode) control motor test connections.

1.

Measure resistance between motor connector terminals D and E, Fig. 12. Resistance should be 4000 ohms.

2.

Check operation by connecting battery positive terminal to motor terminal A and battery negative terminal to motor terminal B. Motor should run. 
Disconnect battery as soon as motor starts, or motor will be damaged.

3.

Reverse battery connections and ensure motor runs in opposite direction.

4.

Connect ohmmeter between motor terminals C and D, then repeat steps 2 and 3 while observing ohmmeter.

5.

Resistance should fluctuate between approximately 1200 ohms with motor in vent position and approximately 4000 ohms with motor in defrost
position.

6.

If motor fails to operate as outlined, motor is defective.

Fresh Air/Recirculation Actuator|Page 3154 > < Fresh Air/Recirculation Actuator