honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Mainshaft Inspection|Page 5967 > < Mainshaft Inspection|Page 5965
Page 2
background image

Service Limit: 0.31 mm (0.012 in.) 

5. Measure distance (1) on the spacer collar.

-

If distance (1) is not within the standard, replace the spacer collar with a new one.

-

If distance (1) is within the standard, go to step 6.

Standard: 24.03-24.06 mm (0.946-0.947 in.) 

6. Measure the thickness of 4th gear.

-

If the thickness of 4th gear is less than the service limit, replace 4th gear with a new one.

-

If the thickness of 4th gear is within the service limit, replace the 3rd/4th synchro hub with a new one.

Standard: 27.02-27.07 mm (1.063-1.066 in.) 

Service Limit: 26.95 mm (1.061 in.) 

7. Measure the clearance between the spacer collar (A) and 5th gear (B) with a dial indicator (C). If the clearance is more than the service limit, go to

step8.

Standard: 0.06-0.19 mm (0.002-0.007 in.) 

Service Limit: 0.31 mm (0.012 in.) 

Mainshaft Inspection|Page 5967 > < Mainshaft Inspection|Page 5965