Odyssey L4-2.2L SOHC (1995)
2. Connect battery power to the No. 1 terminal, and ground the No. 2 and No. 4 terminals; the recirculation control motor should run smoothly.
CAUTION: Never connect the battery in the opposite direction.
Recirculation Control Motor Test
3. Disconnect the No. 2 or No. 4 terminals from ground; the recirculation control motor should stop at FRESH or RECIRCULATE.
NOTE: Don't cycle the recirculation control motor for a long time.
4. If the recirculation control motor does not run in step 1, remove it, then check the recirculation control linkage and doors for smooth movement. If
the recirculation control linkage and doors move smoothly, replace the recirculation control motor.
Recirculation Control Switch
Recirculation Control Switch Test
Check for continuity between the terminals according to the table.