honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 3103 > < Symptom Related Diagnostic Procedures|Page 3101
Page 10
background image

Is there continuity?

YES-Go to step 10.

NO-Repair open in the wire between the rear blower resistor and the rear blower motor main relay.

10. Remove the rear blower motor high relay, and test it.

Is the relay OK?

YES-Go to step 11.

NO-Replace the rear blower motor high relay.

11. Check for continuity between the No.2 terminal of the rear blower motor main relay 6P connector and the No.1 terminal of the rear blower motor

high relay 4P connector.

Is there continuity?

YES-Go to step 12.

NO-Repair open in the wire between the rear blower motor main relay and the rear blower motor high relay.

12. Check for continuity between the No.3 terminal of the rear blower motor high relay 4P connector and body ground.

Is there continuity?

YES-Go to step 13.

NO-Check for an open in the wire between the rear blower motor high relay and body ground. If the wire is OK, check for poor ground at G 582.

Symptom Related Diagnostic Procedures|Page 3103 > < Symptom Related Diagnostic Procedures|Page 3101