The PCM controls the shift solenoid valves and the A/T clutch pressure control solenoid valves. The conditions of the shift solenoid valves and the
positions of shift valves are as follows:
-

shift solenoid valve A is turned ON, and shift valve A is in the right side. 

-

Shift solenoid valve B is turned ON, and shift valve B is in the right side. 

-

Shift solenoid valve C is turned ON, and shift valve C is moved to the right side by modulator pressure (6). 

The PCM also controls A/T clutch pressure control solenoid valve B to apply LS B pressure (57) to CPC valve B. Line pressure (4) from the manual
valve becomes 1st clutch pressure (10) at shift valve C. 1st clutch pressure (10) is applied to the 1st clutch, and the 1st clutch is engaged. Line pressure
(4) also flows to CPC valve B. and becomes CPC B pressure (4B). CPC B pressure (4B) becomes 1st-hold clutch pressure (15) at shift valve D, via
shift valves C, B  and A. 1st-hold clutch pressure (15) is applied to the 1st-hold clutch, and the 1st-hold clutch is engaged. 

NOTE:  When used, "left" or "right" indicates direction on the hydraulic circuit. 

[R] Position: Shifting to the [R] position from the [P] or [N] position 