honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Starting System > < Voltage Regulator|Specifications|Page 2546
Page 2
background image

Fig. 10 Alternator full field access hole location. 1988 units

b. Remove protective cover from alternator end cover. Perform full field test by inserting a suitable tool into full field access hole located on

end cover, Fig. 10. When alternator is in full field, system voltage will rise quickly. Do not allow voltage to exceed 18 volts or damage to
electrical system may result. Note tester amperage readings with alternator in full field. If readings are now within specification, replace 
voltage regulator. If readings are still not within specification, replace alternator.

Starting System > < Voltage Regulator|Specifications|Page 2546