Excel L4-1468cc 1.5L SOHC (8 VALVE) (1986)
Hose/Line HVAC: All Technical Service Bulletins
A/C - Proper Suction & Discharge Hose Installation
Group:
CLIMATE CONTROL
Number:
003
Date:
APRIL, 1987
Model:
EXCEL
Subject A/C SYSTEM LEAK - SUCTION HOSE & DISCHARGE HOSE
Due to restricted access to the high and low pressure hose fittings on the A/C compressor, it is necessary to use special procedures and tools to properly
secure these fittings. The following procedures and recommended tools should be used to insure proper installation.
1.
Attach the high and low pressure lines to the A/C compressor finger tight. Be sure O-rings are properly lubricated with clean refrigerant oil only.
2.
Insert a 1" wood dowel (broom handle) between the low pressure line muffler and the A/C compressor body (see illustration). Take care not to
disturb any vacuum or electrical connections during this step. If properly inserted, the dowel will keep the suction line properly aligned (parallel to
the compressor) during torquing of the attachment fitting.
Note: