hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Charging System - Diagnosis|Page 1326 > < Charging System - Diagnosis|Page 1324
Page 6
background image

2.

Apply a 15O-170 amp load to the battery.

3.

Maintain this load for 15 seconds while watching the voltmeter Turn off the control knob immediately after 15 seconds.

4.

The voltage should not fall below 9.6 volts while the load is applied.

5.

After the load is removed, recovery voltage should be a minimum of 11.2V.

NOTE:

If the voltage falls below 9.6 volts while the load is applied, conduct the Three Minute Charge Test.

iv)

Three Minute Charge Test:

A three-minute charge test will determine if the discharged battery can be recharged or should be replaced. If the battery is to be tested in the
vehicle, disconnect both battery cables to avoid damaging the generator and electrical system. If high voltage is recorded early in the test, stop the
test and replace the battery. High internal resistance due to sulfation on poor internal connections will develop heat that can boil the electrolyte.

1.

Connect the charger leads to the battery terminals, observing correct polarity (+) lead to (+) terminal and (-) lead to (-) terminal.

2.

Connect a voltmeter across the battery, (+) lead to (+) terminal and (-) lead to (-) terminal.

Charging System - Diagnosis|Page 1326 > < Charging System - Diagnosis|Page 1324