Limit: 36.98 mm (1.456 inch).
ACTUATOR
Visual Check
Check and see that there is no damage, cracking, or other abnormality.
Functional Check
-
Disconnect the shift position switch. Make sure of function with a negative pressure of -400 mm Hg applied to Ports A and B. in accordance
with the table.
State: C
Port A: -400 mm Hg
Port B: A/P
Function: E
State: D
Port A: A/P
Port B: -400 mm Hg
Function: F
If there is an abnormality, replace the actuator as an assembly.
NOTE:
^
If the actuator works under -400 mm Hg or less, there is no functional problem.
^
Be careful not to permit the entry of water or dust into the ports of the actuator.