13.

Adhere the information label (supplied with the kit) to the windshield lower finisher, adjacent to the switch (Fig. 2).

14.

Place the Battery Isolation Switch Handbook Supplement (S 44) in the vehicle glovebox.

NOTE:
If the vehicle is equipped with the Jaguar 19000 code alarm system (JAG 550), it will be necessary to disconnect the alarm system back-up battery to
enable the customer to perform coding procedures more easily. This will not affect normal alarm system operation.

Use the following procedure:

15.

Remove the left-hand underdash panel and anti-submarine panel.

16.

Locate and disconnect the back-up battery, tape back the connectors.

17.

Install the left-hand anti-submarine panel and underdash panel.

SERVICE ADVISOR NOTE:

Customers must be informed of the following:

1.

All electrical power will be isolated by the use of the switch.

2.

Customers will be unable to use the vehicle alarm system

(if installed) while the isolation switch is activated.

3.

Use of the isolation switch will require customers to reprogram the 19000 alarm system transmitters in order to use the system.

4.

The radio memory (for security codes and pre-programmed stations) will be affected by isolation switch use.

Carefully review the information provided in Supplement S 44 with the customer. Pay particular attention to the re-coding procedures.

WARRANTY INFORMATION:

Fault Code:

7BQ

Repair Operation Number:

86.15.20 (Installation of Battery Isolation Switch)

Time Allowance:

0.40 hrs.

Add the following time for vehicles equipped with JAG 550 19000 code Alarm Systems:

Fault Code:

9SSX

Repair Operation Number:

86.52.19 (Disconnection of Alarm System Back-up Battery)