Coupler HVAC: Description and Operation

Refrigerant Fittings

The A/C condenser core and the connection between the receiver drier manifold assembly (outlet) and the TXV manifold and tube assembly (inlet) use
the peanut-shaped refrigerant fittings instead of spring lock couplings.

The male and female blocks of the peanut fitting are retained with a nut.

An O-ring seal is installed around the tube on the male block.

The female block is welded to the tube and is not adjustable.

Support the female fitting with a wrench to prevent the twisting of tubes.

The male block will pivot around the tube to allow for alignment with the female block during assembly

When correctly assembled, the male and female fittings should be flush.