jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Valve Body, A/T|Description and Operation|Page 3881 > < Valve Body, A/T|Description and Operation|Page 3879
Page 3
background image

The shift valve pressure (p-SV) is derived from the regulating valve pressure (p-RV), is regulated at the shift valve pressure regulating valve and is
then present at the:
-

1-2 and 4-5 shift solenoid valve.

-

3-4 shift solenoid valve.

-

2-3 shift solenoid valve.

-

Torque converter lockup solenoid valve.

-

3-4 and 2-3 shift pressure shift valve.

The shift valve pressure (p-SV) controls the command valves via the upshift/downshift solenoid valves.

Overlap Pressure (p-U)

The overlap pressure controls the shift component pressure reduction during a shift phase. The pressure in a shift element as it disengages is controlled
during the shift phase depending on engine load (modulating pressure) and the pressure in the shift element as it engages. The adjusted pressure is
inversely proportional to the transmission capability of the shift element being engaged (controlled overlap).

Working Pressure Regulating Valve (Operating Pressure)

The working pressure regulating valve (4) is located in the valve housing of the shift plate. It regulates the primary pressure of the hydraulic system.

Torque Converter Lockup Clutch Regulating Valve