Defender 90 (LD) V8-4.0L (1997)
Air Door Cable: Service and Repair
Heater Control Cable - Temperature Control
Heater Control Cable - Temperature Control
Remove
1. Disconnect battery.
2. Remove 4 screws securing instrument binnacle to fascia cowl.
3. Pull instrument binnacle away from fascia to ease access to control cable at bulkhead.
4. Remove retaining screws and pull off air distribution and temperature control lever knobs.
5. Remove 3 screws and detach side cover, complete with control lever assembly.
6. Remove 2 screws securing control lever assembly to side cover and remove cover. Retain plastic screw spacers fitted between cover and control
lever assembly.
7. Remove bolt and release outer cable retaining clip.
8. Slacken grub screw and release inner cable from clevis.
9. From inside engine compartment: Release outer cable retaining clip at heater unit.