Defender 90 (LD) V8-40L (1997) HVAC Air Door Cable & Blower Motor Switch | Service & Repair
Air Door Cable: Service and Repair
Control Cable and Blower Motor Switch
Control Cable and Blower Motor Switch
Remove
1. Disconnect battery.
2. From inside engine compartment, release outer cable retaining clip at heater unit.
3. Slacken trunnion fixing and release inner cable from heater unit flap lever.
4. Release 2 retaining clips securing control cables to engine bulkhead and heater hoses.
5. Remove 4 screws securing instrument panel to fascia cowl.
6. Pull instrument binnacle away from fascia to ease access to control cable.
7. Remove 2 screws securing control lever assembly to side of fascia binnacle cowl. Retain plastic screw spacers fitted between cowl and lever
assembly.
8. Release lever assembly and disconnect 3 blower motor leads, noting their positions.
9. Pull control cable through bulkhead grommet and out from instrument binnacle cowl.
10. Release retaining clip securing outer cable to lever assembly.
11. Release inner cable from lever peg.
NOTE: Renew complete lever assembly if the blower motor switch is faulty.
Refit
12. Fit control cable to lever assembly peg.
13. Fit retaining clip to secure outer cable.
14. Reconnect blower motor leads.