landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Refrigerant|Capacity Specifications|Page 6607 > < Refrigerant|Capacity Specifications|Page 6605
Page 1
background image

Refrigerant: Service and Repair

Refrigerant Recovery - Recycling And Recharge

Service repair No - 82.30.02

Refrigerant recovery

1. Recover refrigerant.

WARNING:  Servicing must only be carried out by personnel familiar with both the vehicle system and the charging and testing
equipment. All operations must be carried out in a well ventilated area away from open flame and heat sources.

NOTE:  Receiver drier need only be changed under the following circumstances. There is dirt in the refrigerant circuit ( e.g. compressor seizure).
The system is leaking and refrigerant has been lost to atmosphere Refrigerant circuit has been open more than 24 hours due to repair.

2. Remove dust caps from high and low pressure connectors.
3. Connect high and low pressure hoses to appropriate connections.
4. Open valves on connectors.
5. Turn valves on refrigerant station to correct positions.
6. Turn process switch to correct position.
7. Turn Main switch to 'ON'.
8. Allow station to recover refrigerant from system.

WARNING:  Refrigerant must always be recycled before re-use to ensure that the purity of the refrigerant is high enough for safe use in
the air conditioning system. Recycling should always be carried out with equipment which is design certified by Underwriter Laboratory
Inc. for compliance with SAE J1991. Other equipment may not recycle refrigerant to the required level of purity. A R134a Refrigerant
Recovery Recycling Recharging Station must not be used with any other type of refrigerant. Refrigerant R134a from domestic and
commercial sources must not be used in motor vehicle air conditioning systems.

9. Close valves on refrigerant station.

10. Turn Main switch to 'OFF'.
11. Close valves on connectors.
12. Disconnect high and low pressure connectors.
13. Fit dust caps to connectors.
14. Open tap at rear of station to drain refrigerant oil.
15. Measure and record quantity of refrigerant oil recovered from system.
16. Close tap at rear of station.

Evacuation

1. Remove dust caps from high and low pressure connectors.
2. Connect high and low pressure hoses to appropriate connections.
3. Open valves on connectors.
4. Turn valves on refrigerant station to correct positions.
5. Turn Process switch to correct position.
6. Turn Main switch to 'ON'.
7. Allow station to evacuate system.

Recharging

1. Recharge A/C system.

CAUTION:  The system must be evacuated immediately before recharging commences. Delay between evacuation and recharging is not

Refrigerant|Capacity Specifications|Page 6607 > < Refrigerant|Capacity Specifications|Page 6605