4. Remove the catalyst monitor sensor electrical connector heat shield.

^

Remove the 2 bolts.

5. Using the special tool, remove the catalyst monitor sensor.

^

Release the wiring harness.

^

Disconnect the electrical connector.

Installation

1. Using the special tool, install the catalyst monitor sensor.

^

Clean the components.

^

Apply an anti-seize compound to the thread of the sensor.

^

Tighten the catalyst monitor sensor to 45 Nm (33 ft. lbs.).

^

Connect the electrical connector.

^

Attach the wiring harness.

CAUTION:
^

Make sure the anti-seize compound does not contact the catalyst monitor sensor tip.

^

Make sure the catalyst monitor sensor wiring harness is not twisted more than 180 degrees and is not in contact with either the