RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
a. Connect the water hose with the clamp to the w/ converter inverter assembly.
13. INSTALL INVERTER RESERVE TANK SUBASSEMBLY
a. Connect the 2 water hoses with the 2 clamps to the inverter reserve tank sub-assembly.
b. Install the inverter reserve tank with the 2 bolts to the w/ converter inverter assembly.
Torque: 10 N.m (102 kgf.cm, 7 ft.lbf)
14. CONNECT ENGINE ROOM WIRE NO.2
a. Connect the engine room wire No.2 with the nut.
Torque: 8.5 N.m (87 kgf.cm, 75 in.lbf)
15. CONNECT CIRCUIT BREAKER SENSOR NO.1