lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Temperature Blend Door Actuator|Page 6968 > < Temperature Blend Door Actuator
Page 2
background image

4. Remove the RH temperature blend door actuator.

1

Remove the 3 temperature blend door actuator screws.

2

Disconnect the temperature blend door actuator electrical connector.

3

Remove the RH temperature blend door actuator.

5. To install, reverse the removal procedure.

LH

TEMPERATURE BLEND DOOR ACTUATOR - LH

Removal and Installation

1. Remove the LH lower instrument panel insulator.

2. Remove the lighting control module.

1

Detach the vacuum line.

2

Remove the screws.

3

Disconnect the lighting control module electrical connectors and remove the lighting control module.

3. Remove the LH temperature blend door actuator.

1

Disconnect the temperature blend door actuator electrical connector.

2

Remove the 3 temperature blend door actuator screws.

3

Remove the LH temperature blend door actuator.

4. To install, reverse the removal procedure.

Temperature Blend Door Actuator|Page 6968 > < Temperature Blend Door Actuator