6 L4-2.5L (2010)
Variable Induction Control Solenoid: Testing and Inspection
Variable Tumble Shutter Valve Switch Inspection
VARIABLE TUMBLE SHUTTER VALVE SWITCH INSPECTION [L5]
1. Connect the M-MDS to the DLC-2.
2. Switch the ignition to ON.
3. Verify that the voltage (M-MDS PID: IMRC_POS) within the specification. See: Computers and Control Systems/Testing and
Inspection/Component Tests and General Diagnostics/PCM Inspection
-
If not as specified, replace the intake manifold. See: Engine, Cooling and Exhaust/Engine/Intake Manifold/Service and Repair