mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Variable Intake Air Solenoid Valve Inspection|Page 3575 > < Variable Intake Air Solenoid Valve Inspection
Page 1
background image

Variable Induction Control Solenoid: Testing and Inspection
Variable Tumble Shutter Valve Switch Inspection

VARIABLE TUMBLE SHUTTER VALVE SWITCH INSPECTION [L5]

1. Connect the M-MDS to the DLC-2.

2. Switch the ignition to ON.

3. Verify that the voltage (M-MDS PID: IMRC_POS) within the specification.  See: Computers and Control Systems/Testing and

Inspection/Component Tests and General Diagnostics/PCM Inspection 

-

If not as specified, replace the intake manifold.  See: Engine, Cooling and Exhaust/Engine/Intake Manifold/Service and Repair

Variable Intake Air Solenoid Valve Inspection|Page 3575 > < Variable Intake Air Solenoid Valve Inspection