mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2077 > < Component Tests and General Diagnostics
Page 2
background image

-

No.2 cylinder fuel injector terminal 2 (harness-side) and main relay (harness-side) terminal D through common connector.

-

No.3 cylinder fuel injector terminal 2 (harness-side) and main relay (harness-side) terminal D through common connector.

-

No.4 cylinder fuel injector terminal 2 (harness-side) and main relay (harness-side) terminal D through common connector.

-

No.5 cylinder fuel injector terminal 2 (harness-side) and main relay (harness-side) terminal D through common connector.

-

No.6 cylinder fuel injector terminal 2 (harness-side) and main relay (harness-side) terminal D through common connector.

Short circuit
-

If there is continuity, the circuit is short. Repair or replace the harness.
-

No.1 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.2 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.3 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.4 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.5 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.6 cylinder fuel injector terminal 1 (harness-side) and body GND.

-

No.1 cylinder fuel injector terminal 2 (harness-side) and power supply.

-

No.2 cylinder fuel injector terminal 2 (harness-side) and power supply.

-

No.3 cylinder fuel injector terminal 2 (harness-side) and power supply.

-

No.4 cylinder fuel injector terminal 2 (harness-side) and power supply.

-

No.5 cylinder fuel injector terminal 2 (harness-side) and power supply.

-

No.6 cylinder fuel injector terminal 2 (harness-side) and power supply.

Fuel Leakage Test

WARNING:  Fuel line spills and leakage are dangerous. Fuel can ignite and cause serious injuries or death and damage. Always carry out the
following procedure with the engine stopped.

NOTE:  Perform the following test only when directed.

1. Complete the "BEFORE REPAIR PROCEDURE".
2. Disconnect the negative battery cable.

3. Remove the fuel injectors together with the fuel distributor with connected to fuel hose.
4. Fasten the fuel injectors firmly to the fuel distributor with wire.
5. Connect the negative battery cable.

CAUTION:  Connecting the wrong DLC terminal may possibly cause a malfunction. Carefully connect the specified terminal only.

Component Tests and General Diagnostics|Page 2077 > < Component Tests and General Diagnostics